EN6001 Retrofit

The ENTRON EN6001 Retrofit Kit is an Engineered set of components designed to upgrade existing EN1000/EN1001 Single phase-single SCR series of weld controls. The kit can be installed in a very short time such that the Welder can be put back to production within the hour.

Please refer to the EN6001 Retrofit Video:

 
 

Processes Supported by Control

Spot Weld

Spot Repeat weld

Spot Pre Heat with Pulses

Projection Weld with Tooling

Crosswire Welding

Seam Weld

Hotstaking/Rivet Weld

Butt Weld Post Heat

Butt Weld Single Heat

 
 

Videos

 
 

Documentation

 

Details

Options

• Program Lockout (key switch)
• Operation Mode Switch (Program Lockout and Weld/No Weld)
• Error Reset Switch
• Optional plug-in Ethernet card provide PLC compatibility via MODBUS and EtherNet/IP for remote I/O

Technical Specifications

BENEFITS:

  • Low Cost Easier to Program
  • More I/O
  • USB backup Port
  • Schedule Number: 0 to 63
  • Squeeze Delay: 0 to 99 cycles
  • Squeeze: 0 to 99 cycles
  • Valve Mode: None / Combinations of Valve 1, and/or 2
  • Weld1: 0 to 99 cycles
  • Weld1 Current Regulation Mode: Phase Shift / Constant Current
  • Heat1: 0 to 99%
  • Current1: 0 to 60.00 kA
  • Cool1: 0 to 99 cycles
  • Slope: 0 to 99 cycles
  • Weld2: 0 to 99 cycles
  • Weld2 Current Regulation Mode: Phase Shift / Constant Current
  • Heat2: 0 to 99%
  • Current2: 0 to 60.00 kA
  • Cool2: 0 to 99 cycles
  • Hold: 0 to 99 cycles
  • Off: 0 to 99 cycles
  • Impulses: 1 to 99 cycles
  • Heat/Current Offset: -15 to +15%
  • Cycle Mode: Non-repeat / Repeat / Chained / Successive / Wait-here

Features

• Constant current regulation / Secondary feedback
• Current monitoring with high, low, and pre-limits
• Up to 64 programs (internal or external selection)
• On Timer Membrane Keyboard with backlit 128x64 (8 lines) LCD graphic display
• Six (6) inputs and four (4) outputs with output protection on CPU
• Electrode management functions, including stepping, current and force counting, tip-dressing and preset curves
• Welding programs may be linked together for complex spot schedules (chained or successive) Refresh firmware through USB device
• Load/export control settings from/to USB device
• AC 60/50 Hz welding supported
• Spot / Pulsation / Seam (quad heat) / Seam welding / Flash or Butt welding / Brazing
• Multiple weld intervals plus pulsation, upslope and downslope
• Air-over-oil gun operation
• Retraction – maintained, and momentary
• Water Saver (contactor timer)
• Head lock function

 

Find out more